Industrial Ultrasonic Cleaner Manufacturer-GranboUltrasonic

info@granboultrasonic.com
Home / Support / What kinds of enzymes are there in multi enzyme detergent?
click back

What kinds of enzymes are there in multi enzyme detergent?

Browse Volume:984 Classify:Support

Multi enzyme detergent can be used for automatic ultrasonic cleaner and hand washing operation. It is a common and commonly used detergent product in hospitals. Its raw materials are completely biodegradable substances. There is no residue after washing. It has no corrosion or aging effect on all kinds of precision instruments and medical devices. It is used to clean medical devices and has a good cleaning effect on medical devices.

Cleaning with the ultrasonic cleaning agent

Cleaning with the ultrasonic cleaning agent

What kinds of enzymes are there in multi enzyme detergent?

There are many kinds of biological enzymes in the multi enzyme cleaning solution, including neutral protein hydrolase, lipase, amylase and other multi enzyme complexes. These enzymes have mild effects and are targeted at protein, fat, starch and other related substances. As we all know, medical devices may be stained with many organic pollutants, such as blood stains, fat, tissue and human mucus. This kind of material is difficult to clean with ordinary cleaning methods. The dirt that is difficult to clean needs to be cleaned with some special detergent.

 

Medical devices suitable for multi enzyme detergent:

Surgical instruments, stainless steel instruments, dental handpieces and instruments, spiral tubes of anesthesia and ventilator, medical plastics, minimally invasive instruments, lumen instruments, glass containers, endoscopic instruments.

Medical instrument

Medical instrument

Characteristics of enzyme:

Biological enzyme is a protein with biocatalysis function produced by living cells, which has very high catalytic efficiency. Almost all kinds of reactions in organisms are catalyzed by enzymes.

★ biological enzymes are specific and efficient. One enzyme only catalyzes one reaction of one substance

★ it can decompose protein, fat, sugar and other macromolecular organic pollutants that are difficult to dissolve in water into water-soluble small molecules to achieve the purpose of cleaning.

★ remove the microorganism on the surface of the object and increase the ability to remove the microorganism on the surface of the object during cleaning.

★ the use of multi enzyme detergent can not only improve the cleaning quality and efficiency, but also shorten the cleaning time and reduce the labor intensity of medical personnel.

 

According to the characteristics of enzymes, an ideal multi enzyme cleaner should have:

a. Excellent decontamination ability;

b. Weak corrosivity and good compatibility with instruments;

c. Low foam level;

d. The smell is soft and not irritating;

e. High enzyme activity and good stability;

f. Keep the aqueous solution transparent;

g. The ingredients are safe and environmentally friendly.

Medical apparatus

Medical apparatus

Cleaning method:

a. Manual cleaning

Rinse with running water → soak in multi enzyme detergent for 5min → rinse → soak in disinfectant for 20min → brush → rinse → dry

b. Full automatic cleaning machine

Ultrasonic cleaning machine

Hydraulic cleaner

High pressure cleaning machine

 

Application scope of multi enzyme detergent:

Multi enzyme detergent is suitable for manual cleaning and automatic cleaning.

★ manual cleaning is applicable to the cleaning of surgical instruments, pipes, rubber, medical plastics, instruments, laboratory utensils and other medical instruments.

★ the automatic cleaning machine is applicable to disinfection machines, various full-automatic cleaning machines, and the cleaning of various soft and hard endoscope, surgical instruments, pipes, rubber, medical plastics, instruments, laboratory utensils and other medical instruments.

Medical Device

Medical Device

Precautions for using multi enzyme detergent:

1. The multi enzyme detergent shall not directly contact the skin and mucous membrane. Please wear gloves when diluting. If you accidentally touch the skin, please wash it with a large amount of running water for at least 15 minutes;

2. The water temperature shall be controlled at 10-60 ℃ when cleaning with multi enzyme cleaning solution;

3. The multi enzyme cleaning solution must be diluted before use. Before that, do not touch water. Each dilution must be closed in time, otherwise the multi enzyme cleaning solution will be invalid;

4. The use environment of multi enzyme cleaning agent must be between pH 5.5-9.0, preferably pH 6.5-7.5;

Hello!

Cancel Reply
question razz sad evil exclaim smile redface biggrin surprised eek confused cool lol mad twisted
    chat_online
    chat_online
    chat_online